Monitoramento da frequência respiratória usando sensores de fibras ópticas de polímero integrados ao smartphone com conectividade em nuvem

Nenhuma Miniatura disponível
Data
2023-10-26
Autores
Gomes, Lívia Gonçalves
Título da Revista
ISSN da Revista
Título de Volume
Editor
Universidade Federal do Espírito Santo
Resumo
Respiratory rate is one of the important physiological signals used to monitor human health in disease and physical activity areas. In this context, there are multiparameter sensors that are commercially known and usually applied in hospital settings. Their design does not provide great mobility for the patient, in addition to the high cost, making accessibility to other environments difficult. On the other hand, the advancement of technologies has led to the development of various types of electrical sensors for measuring these signals; however, the majority of them are electrically and electronically based, not being suitable for environments with electromagnetic interference. This work presents a respiratory rate system composed of a polymer optical fiber sensor using a smartphone as the interrogator system, which acts in the emission and acquisition of the optical signal. Additionally, integration with the Internet of Things was carried out, using Edge Computing techniques for local signal processing in an application developed on the AndroidStudio platform. The ThingSpeak platform is used for cloud storage and the ThingView mobile application allows online viewing of information, providing the remote access. To verify the accuracy of the sensor, a metronome was set to specific frequency rates, used as a reference. The sensor underwent extension and retraction movements, carried out manually, at the frequency of the metronome’s beats at these rates. The sensory system presents a maximum percentage error of 4.5% (1.35 BPM - Breaths per Minute) when comparing the values obtained with the reference frequencies used. Furthermore, tests were performed on volunteers to verify the system’s performance in a real environment, where they were asked to breathe normally, at rest, and also simulating the practice of physical exercises at three known breathing rates. The highest percentage error verified for the resting state is 3.63% (0.8 BPM) and for the moving state 5.35% (1.88 BPM). To verify the remote access to information, the visualization of respiratory rate data measured by the local system in ThingView was analyzed. The frequency read in the application is the same measured by the sensor, presented instantly, it is also visualized the measurement information of the week and month, showing the efficiency of the proposed approach for remote sensing applications with cloud integration.
Descrição
Palavras-chave
Sensores de fibra óptica polimérica , Frequência respiratória , Processamento de sinal , Integração em nuvem , Acesso remoto
Citação